High-performance compressed air dryer with extreme speed pre-cooling, high-efficiency evaporation and dual-stage water separation, delivering low pressure loss and a stable dew point.
Moisture is the failure that shows up somewhere else — a stuck valve, a blistered paint finish, a batch of parts rejected at inspection. The GEN 6 Super Cool sits directly after the compressor and after-cooler and removes that moisture before it ever reaches the ring main.
Air enters through an air-to-air pre-cooler, where the outgoing cold stream chills the incoming warm stream. The pre-cooled air then passes over the refrigerated evaporator, condenses, and drops its water into a cyclone separator with a zero-loss electronic drain. Reheating the dry air on the way out prevents condensation on the downstream pipework.
Because the compressor cycles with demand instead of running flat out, a plant on two shifts typically sees the dryer draw standby power for a third of the day.
Every unit is pressure-tested and run for a full thermal cycle before it leaves Foshan. Units are shipped ready to pipe in — no field charging, no commissioning specialist required.
Typical duties for this series across our installed base.
Laser-welded 304 plates replace the copper coil. More surface area in less volume, and nothing to corrode when condensate sits against it.
A thermal mass buffer lets the refrigeration circuit shut down between calls. At 40 % load the unit draws roughly 45 % of rated power.
A thermal mass buffer lets the refrigeration circuit shut down between calls. At 40 % load the unit draws roughly 45 % of rated power.
Laser-welded 304 plates replace the copper coil. More surface area in less volume, and nothing to corrode when condensate sits against it.
A thermal mass buffer lets the refrigeration circuit shut down between calls. At 40 % load the unit draws roughly 45 % of rated power.
A thermal mass buffer lets the refrigeration circuit shut down between calls. At 40 % load the unit draws roughly 45 % of rated power.
| Model | AIR FLOW (M³/MIN) | INLET TEMP (°C) | PRESSURE DEW POINT (°C) | CONNECTION | POWER (KW) | WEIGHT (KG) |
|---|---|---|---|---|---|---|
| SC-2A | 0.3 | ≤ 45 | 2 - 7 | G 3/4" | 0.19 | 28 |
| SC-6A | 0.8 | ≤ 45 | 2 - 7 | G 3/4" | 0.25 | 32 |
| SC-10A | 1.2 | ≤ 45 | 2 - 7 | G 1" | 0.37 | 42 |
| SC-15A | 1.7 | ≤ 45 | 2 - 7 | G 1" | 0.55 | 48 |
| SC-20A | 2.5 | ≤ 45 | 2 - 7 | G 1" | 0.55 | 56 |
| SC-2A | 0.3 | ≤ 45 | 2 - 7 | G 3/4" | 0.19 | 28 |
| SC-6A | 0.8 | ≤ 45 | 2 - 7 | G 3/4" | 0.25 | 32 |
| SC-10A | 1.2 | ≤ 45 | 2 - 7 | G 1" | 0.37 | 42 |
| SC-15A | 1.7 | ≤ 45 | 2 - 7 | G 1" | 0.55 | 48 |
| SC-20A | 2.5 | ≤ 45 | 2 - 7 | G 1" | 0.55 | 56 |
Need a Customized Model? Contact Our Experts.
English